allied
academies
Page 58
Journal of Systems Biology & Proteome Research
|
Volume 2
J u n e 2 5 - 2 7 , 2 0 1 8 | D u b l i n , I r e l a n d
MASS SPECTROMETRY
AND PROTEOMICS
International Conference on
DIAGNOSTIC ACCURACY OF CANNABINOID TESTING BY LIQUID
CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY IN HUMAN HAIR
Alveena Younas, Asif Nawaz, Ayesha Hafeez, Aamir Ijaz, Naveed Asif
and
Abdul Manan
Armed Forces Institute of Pathology (AFIP) Rawalpindi, Pakistan
Objective:
To determine the diagnostic accuracy of Cannabinoids testing by Liquid Chromatography-Tandem Mass Spectrometry
(LC-MS) in human hair and to compare it with urine for detection of cannabis use in civil heavy vehicle drivers
Materials and Methods:
This diagnostic accuracy(validation) study was carried out at Department of Forensic Medical Sciences
Laboratory (FMSL), Forensic Toxicology Section, Armed Forces Institute of Pathology Rawalpindi, Pakistan. Hair and urine samples
of about 151 civil heavy vehicle drivers were collected from various urban and rural areas of Punjab.
Result:
Sampling technique was non-probability convenient. About 10 ml of urine volume was collected and stored at -20 °C. Hair
strands, about the thickness of a pencil shaft, were collected from the posterior vertex of
scalp.Itwas cut as close to the root as
possible, and kept at room temperature till further analysis Separation of compounds was done on Agilent Poroshell 120 EC-C18
column (2.1 x 7.5mm.7 micron) and analyzed on a 6460 Triple Quadrapole LC-MS along with software Mass hunter ©. Results:
Al the 151-male civil heavy vehicle drivers, who were included in the study, were categorized into three main groups. There were
69(71.5%) truck drivers,43(28.5 %) were 20-wheeler drivers, whereas bus drivers were 39(25. 8%).Mean age was 36±10.82 years.
Subjects were stratified according to the age into four main groups: 20-25 y: 28(18.5%); 26-40 y: 73(48.3%), 41-60 y:47(31.1%)
and >60 y:3(2%).
Conclusion
: This study highlights the importance of hair as an alternative biological matrix due to its good diagnostic yield, easy
non -invasive specimen collection and distinctive potential of analyte stability, as well as wider period of detection as compared
to urine.
dralveenayounas.4@gmail.comJ Syst Biol Proteome Res 2018, Volume 2