QBD DRIVEN STABILITY INDICATING RP-HPLC ASSAY METHOD FOR
FLIBANSERIN: DEVELOPMENT, VALIDATION AND CHARACTERIZATION
OF MAJOR DEGRADANTS BY LC/QTOF-MS/MS
Manish Kumar Sharma
National Institute of Pharmaceutical Education and Research (NIPER) Ahmedabad, India
T
he inherent chemical stability of Flibanserin (FLB) was investigated by using Plackett Burman design for screening of inde-
pendent variables. Box-Behnken design was used for optimization of high performance liquid chromatography (HPLC) stabil-
ity indicating assay method. Forced degradation of FLB was carried out under hydrolysis (acidic, basic, and neutral), photolysis,
oxidation and thermal stress conditions. The major oxidative degradation product was isolated by preparative HPLC. The degra-
dation product was identified as 2-HBenz-imidazol-2-one,1, 3-dihydro-1-[2-[4-[3(trifluoro methyl) phenyl]-1-N-oxide-piperazinyl]
ethyl] following characterization by UV, IR, HRMS and NMR techniques. The parent ion mass of the oxidative degradants was
observed mass 407.1710 and major fragments (389.1582, 375.1422, 255.1100, 243.1103, 228.0866, 216.1127, and 200.0680)
in LC-QTOF-MS when analysed in positive ionization mode. Oxidation and hydrolysis were found to be the primary degradation
pathways for this molecule. The chromatographic separation was achieved on Cromasil C18 column (4.6mm×250mm, 5μm)
using a mobile phase consisting of a mixture of ammonium acetate (pH 5.5) and acetonitrile in linear gradient elution mode.
The method was found to be linear in the concentration range of LOQ (0.5 to 70 µg/mL). The method was validated as per ICH
guideline Q2 (R1). Degradation of FLB followed first-order kinetics under all experimental conditions. A V-shaped pH-rate profile
kinetics over the pH range 2–10 was observed with maximum stability at pH 6.8. In conclusion, a reverse phase high performance
liquid chromatographic method has been developed and validated for quantitation of FLB in presence of their degradation prod-
ucts. The major degradation product has been identified and fully characterized that has not been reported till date. This is the
first time to report a stability indicating assay method for FLB.