Current Trends in Cardiology

All submissions of the EM system will be redirected to Online Manuscript Submission System. Authors are requested to submit articles directly to Online Manuscript Submission System of respective journal.
Reach Us +1 (202) 780-3397

An alternative to transvenous lead extraction in selected patients with CIED Infections - A retrospective outcome study

6th International Conference on CARDIOLOGY HEART DISEASE AND HEART FAILURE
September 19, 2022 | Webinar

Goutham Meda

Walsall Manor NHS Hospital, United Kingdom

Posters & Accepted Abstracts : Curr Trend Cardiol

Abstract:

Cardiac implantable electronic devices (CIED) implants are rising in an older, more co-morbid population. The prevalence of CIED infection ranges from 1-4%. Whilst complete extraction of all transvenous hardware is recommended for infected, eroded or preeroding CIEDs, this approach is not without risk and may be unacceptable to some patients. Long term data on a more conservative strategy is lacking. We report on our experience of conservative management with pocket revision as a primary strategy in carefully selected patients. Method: A retrospective review of all CIED revision procedures at a large tertiary centre, over a 7-year period was undertaken with a mean follow up of 39 months. Results: 86 patients underwent 96 revision procedures. 7 patients required further revisions and 13 went on to undergo CIED extraction by the end of follow up. Overall mortality at 12 months was 8.1%, increasing to 24.4% at end of follow up. Results: There was no in hospital mortality and all patients were alive at 30 days. Overall, 7 (8%) patients had a repeat procedure (including 1 who underwent 3 revisions) and 13 (15%) went on to undergo CIED extraction in the follow up period. Overall, 7 (8.1%) deaths occurred within 12 months of revision. 21 (24.4%) patients died in the follow up period. A higher proportion of patients presenting with erosion died within 12 months of revision (16.67% vs 4.84%). 25% with an eroded device and 11% with a preeroding device undergoing revision required an extraction during the follow up period. There was no in hospital mortality and at 30 days all patients were alive in both groups. At 12 months, more patients in the erosion group had died compared to the pre-erosion group (17% vs 5%, p=0.16). This trend continued over the medium term follow up (42% vs 18%, p=0.04). At the last available follow up, 13 (15%) patients went on to a full system extraction; 6/24 (25%) in the erosion group and 7/62 (11%) in the preerosion group. Conclusion: Our data provides important outcome information on an alternative strategy to lead extraction in carefully selected patients where the risk of extraction is perceived to be unacceptable. The absence of systemic infection appears to predict better outcomes than previously reported and over two-thirds of patients remained complication free at 12 months.
References :
1. Llewellyn J (2021) An alternative to lead extraction in carefully selected patients with CIED issues – a retrospective outcome study
2. Tomlinson-Perez S (2021) An evaluation of the Uptake, Retention and Effectiveness of Exercise Referral Schemes for the Management of Mental Health Conditions in a Primary Care Setting: A Systematic Review
3. Garner D (2021) Management of Iatrogenic Severe Tricuspid Regurgitation: Hybrid Lead Extraction and Paravalvular Insertion of a New ICD Lead

PDF HTML