Case Report - Journal of Chemical Technology and Applications (2022) Volume 5, Issue 5

Biosensors for Pathogens diagnosis

A. Mohamed Sikkander1*, Heba S. Abbas2

1Department of Chemistry, Velammal Engineering faculty, Chennai-India

2National organization for drug control research (recently, Egyptian Drug Authority), Cairo -Egypt

*Corresponding Author:
A. Mohamed Sikkander
Department of Chemistry
Velammal Engineering faculty
Chennai-India
E-mail: ams240868@gmail.com

Received: 25-Aug-2022, Manuscript No. AACTA-22-125; Editor assigned: 26-Aug-2022, PreQC No. AACTA-22-125(PQ); Reviewed: 14-Sep-2022, QC No. AACTA-22-125; Revised: 17-Sep-2022, Manuscript No. AACTA-22-125(R); Published: 26-Sep-2022, DOI: 10.35841/aacta-5.5.125

Citation: Sikkander A. Biosensors for pathogens diagnosis. J Chem Tech App. 2022;5(5):125

Visit for more related articles at Journal of Chemical Technology and Applications

Abstract

In medicine, food safety, public health and safety, pathogenic bacteria are necessary objectives for detection and identification. In low-income nations, for example Africa, where medical services and methods of diagnosis and care are inadequate, these forms of infectious are particularly troublesome. Additionally, in higher income nations, including the United States, where food-borne bacteria cause approx. 76 million illnesses, 300,000 hospitalizations and 5,000 deaths annually, Food-borne pathogens often pose a significant health risk. The causal agents of bacterial food and waterborne disease are Escherichia coli O157: H7, Salmonellae, Campylobacter jejuni and Listeria monocytogenes. The bacterial infections are frequently misdiagnosed or an unnecessary delay in diagnosis is despite antibiotic available. Current bacterial detection methods are based on laboratory techniques, such as cell cultivation, microscopic examination and biochemical research. The disadvantages of these techniques are wasting time, expensive equipment’s, and qualified employers. The PCR technique, which is extremely sensitive, allows bacteria to be identified on the basis of its genetic material and requires no bacterial cultivation. However, the PCRs need preselected genetic samples, false pairing can lead to false positives, and genetically modified strains may escape beside the long duration of the experiment. Portable stand-alone biosensors at the treatment point may allow fast detection and diagnosis. Furthermore, in developing countries, quick diagnosis of COVID-19 disease is difficult because of multiple clinical presentations and inadequate resources for health care. In particular, biosensors are helpful in the diagnosis of critical disease such as meningitis or prevent spreading of further diseases.

Keywords

Bacteria Biosensor, Covid-19 Biosensor, Bio Receptor, Optical Biosensors, Mechanical Biosensors, Electro Chemical Biosensors.

Introduction

The first biosensor analysis device in 1956 was developed by the Leland Charles Clark Jr. to calculate the blood oxygen level using an electron. Scientists from various fields such as physics, chemistry and materiel science then they develop advanced, effective and mature biosensing tools for medical applications [1]. Patient diagnosis and monitoring "lab-on-achip" method provides a faster and more efficient diagnostic procedure which prevents complete infection and mortality and lowers disease propagation as well. Biosensors involve basically of a biorecognition component that is linked to some form of transducer that makes a measurable or detectable reading of specific analysis binding to bioreceptor systems [2]. In diverse ways, biosensors may be classified by either a signal transduction system (i.e. optical, mechanical or electrical) or a bioreceptor type (i.e. catalytic). There are several examples for catalytic bioreceptor types such as enzyme, and antibody, aptamer, lectin, bacteriophages -dependent affinity. In general, micro-organism sensors based upon their enhanced selectivity and specificity are favored over enzyme biosensors for detection, as they lack additional reagents (Figure.1) [3].

Figure 1: Schematic representation of several combination of biorecognition and transducer components.

For amperometric and optical procedures, the most widely used in the last 30 years, the biosensor area is expanding rapidly whereas modern procedures such as fiber optics are widely increased. Furthermore, for diverse analytes, biosensors have been established for individual ions and little molecules to nuclear acids, proteins to whole bacteria and viruses (Figure.2).

Figure 2:Biosensors for the field in general compared with the specific detection of whole bacteria.

There are two types of bacteria biosensors which require

1. Bacterial disruption or lysis in order to release the target bacterial constituent such as DNA, RNA (e.g., rRNA), intracellular proteins such as enzymes [4]. However, the disadvantage of this sensor is wasting time, and high cost of tests required for releasing the bacterial components.

2. Or whole bacteria sensor which are fast, and inexpensive sensor.

Typical sizes of bacteria vary from 0.5 to 5 μm, like spherical cocci, rod-shaped bacilli and spiral-like or spirochetes. Depending on the composition and thickness of the cell wall, bacteria can be either gram positive or gram negative. Due to their thick peptidoglycan layer outside the cell membrane, gram-positive bacteria retain the violet gram stain [4]. Gram negative bacteria, on the other hand, don't take up stain, since they sandwich their thinner layer with peptidoglycan between the two cell membranes. A variety of surface antigens, including proteins, glycoproteins, lipopolysaccharides and peptidoglycans, present on cell envelopes of whole bacteria can serve as targets to bio-recognize them.

The following illustrates are some examples of different biosensors for bacteria detection.

Optical Biosensors

Pathogenic microorganisms are contributory agents of various infectious diseases that are becoming increasingly grim worldwide. For the successful treatment of pathogenic infection, the rapid and precise detection of multiple pathogenic microorganisms is of great importance in all areas related to health and safety [4]. Among an assortment of sensor systems, optical biosensors allow easy-to-use, rapid, transferable, multiplexed, and cost-effective diagnosis. In progress trend and advances in pathogen-diagnostic optical biosensors. The technical and procedural approaches fundamental diverse optical-sensing platforms and methods for detecting pathogenic microorganisms, together with the strengths and drawbacks of each technique. In upward efficient optical biosensor systems and future perspectives are discussed about antibodies linked via biotin/avidin to optical fibers. Additionally, nanomaterials have specific physical and chemical characteristics, which are different from bulk materials of the same composition (ultra-small scale, wide area-to-masse ratio, strong reactivity) that help them resolve some of the restrictions of the conventional therapeutic and diagnostic agents [5-7]. In the case of synthesized hafnium oxide core-shell nanoparticles, increased plasmon absorbent bonds have been demonstrated, while in nanoparticleinduced magnetic hypothermic treatments, magnetic and gold nanoparticles have been shown to be successful, causing cancerous cells to experience apoptosis as an immediate reaction to applied heat [8]. Other literatures showed the detection of Escherichia coli by using biosensor made of bioconjugated magnetic beads for capture, fluorescent polymeric micelles for reporting, and other biosensor made of antibodyfunctionalized nanostructured oxidized permeable silicon (PSiO2). However, Shewanella oneidensis can be detected by silver nanoparticles sandwiched by analyte binding on optical fiber tip. Nanoparticles are greatly resourced for detecting and distinguishing pathogens in native biological samples due to their size and properties. For the identification of bacteria, magnetic nanoparticles are used to further research using magnetic resonance imaging [9-11].

The interaction of nanoparticles and bacteria receptors

Raj et al. examined the interaction of gold nanoparticles with cysteine for the recognition of E. coli. The electrostatic attraction between the positively charged cysteine and the negatively charged lipopolysaccharides on the E. coli outer membrane showed the binding affinity of E. coli 0157:H7 to H2 receptors on the surface of cysteine-modified -gold nanoparticles and stabilization. The interconnection of cysteine-capped AuNPs took place in the existence of a defined number of bacteria with a clear red-to-blue shift of sample color and a highly sensitive bacterial detection of naked eyes. Using cysteine-capped gold nanoparticles for potential clinical use, the urine samples (3 to 104 cells / mL) were concentrated [12].

Gold nanoparticles conjugated with aptamers have ability to recognize Salmonella typhimurium. In the existence of the S. typhimurium, the aptamers which exist on the nanoparticle surface bind to the bacteria causing aggregation of the nanoparticles, thus a noticeable colour change. Another literature by Verdoot et al. who develops the antibody functionalized gold nanoparticles for detection of Lactobacillus spp. and Staphylococcus aureus [13]. The colorimetric test showed that Polyethyleneimine-gold nanoparticles are closely related to negative-loading bacteria. The Polyethyleneimine-gold nanoparticles and ß-galactosidase on the bacterial surface were closely interacting. The method was designed to be easy and fast and permit a detection limit of nearly 10 CFU / ml. The goal was to ensure that gold nanoparticles with a positive charge are tied to negative charge of the bacteria surfaces in the presence of teichoic acids of both gram positive and negative bacteria [14].

Optical fiber sensor for detection covid-19

The body primarily releases IgM in response to an infection. This is then superseded by IgG-type antibodies that can be distinguished in blood within days after the clean-up of the infections. As an indicator for exposure to SARS-CoV-2, IgM and IgG in blood and serum may also be used. This is the very theory behind lateral flow experiments, such as those developed by Abbott. Biosensor cartridges can be produced and upscaled in a plug and play format for these serological steps, where suitable receptors are available. Given the high sensitivity of EWA and LSPR technologies, these sensors should be able to diagnose low immunoglobin concentrations, reducing false negatives and early detection opportunities. Another alternative method is to detect the virus itself in swab samples in at least 100 units / ml of a LoD in an hour by the antibodies for the specific S1 subunit of the S protein [15].

Mechanical Biosensors

Mechanical biosensors bestow numerous advantages for use at the point of care; they can offer high sensitivity and quick processing times without the need for sample processing or extra reagents16.The two major categories of mechanical biosensors are based on quartz crystal microbalance (QCM) or cantilever technology.QCM sensors are label-free piezoelectric biosensors which perceive the resonance frequency change that results from amplified mass on the sensor surface due to analyte binding (Figure 3).

Figure 3:Quartz crystal microbalance (QCM) sensor.

The expansion of sandwich-type assays which employ nanoparticles for signal amplification has allowed for the detection of very a small number of bacterial cells, down to 10 CFU/ml in some cases [17]. Microcantilever sensor equipment is an emerging label-free technique that offers very high sensitivity, fast response times, and ease of trimness for the development of point-of-care sensors (Figure 4).

Figure 4:Microcantilever sensor.

Cantilever sensors characteristically comprise a bioreceptorfunctionalized microcantilever which oscillates at a particular resonant frequency. The booming frequency of the cantilever changes due to induced mechanical bending upon an amplify in mass on the sensor surface [18]. The newly developed piezoelectric-excited millimeter-size cantilevers (PEMC) using antibodies as bioreceptors have been talented to detect as few as one E. coli cell in buffer and one hundred Listeria monocytogenes cells in milk. A chief disadvantage of cantilever-based systems is that they are often limited by the need to operate in air as divergent to in physiological media, and there is a dearth of reports in which cantilever-based sensors have been tested in pertinent matrices such as food or patient samples.

Electrochemical Biosensors

Electrochemical biosensors consist of potentiometric, amperometric, and impedimetric sensing techniques. Electrochemical biosensors have afterward become the most developed group with greatest commercial success, largely due to amperometric glucose finding in diabetic monitoring. Their key compensation is low cost, point-of-care testing, and miniaturization capacity [19].

Potentiometric sensors

Potentiometric biosensing uses ion-selective electrodes to determine the potential of a solution based on precise relations with ions in the solution. This technique measures the change in potential that occurs upon analyte detection at the working electrode. Although potentiometry is extensively used in the biosensor field, examples of potentiometric biosensors for the finding of whole bacterial cells (Figure 5).

Figure 5:Potentiometric sensors.

Amperometric sensors

The introduction of enzyme-based amperometric sensing of glucose 40 years ago, this technique has been applied frequently to a wide range of analytes, including whole bacteria [20]. Amperometric biosensors are based on straight measurement of the current generated by the oxidation or reduction of species fashioned in response to analytebioreceptor interaction. The bioreceptor component is usually an enzyme such as glucose oxidase, which is used in all medical glucose monitors (Figure 6).

Figure 6:Amperometric sensors.

Impedimetric sensors

Impedimetric biosensors are a very talented choice for the detection of whole bacteria, being label free, less costly than supplementary systems, highly sensitive, and not affected by the presence of additional analytes or colored compounds in the sample matrix [21,22]. Importantly, impedimetric systems are easy to miniaturize, which facilitates their translation to point-of-care systems (Figure 7).

Figure 7:Impedimetric sensors.

Conclusion

The above discussed biosensors, based on direct detection and indirect methods, such as on the side flow immunoassays and protein chips, have been reviewed in food pathogens detection. The assay recital, including detection limit and assay time, were also compared. The problem of the portability of the instrumentation has been approached with the expansion of cheaper, small-sized scanners and with software for the analysis of video images using mobile devices. Each biosensor method has its own advantages and disadvantages in terms of the equipment required, sensitivity, simplicity and cost-effectiveness. Lab-on-a-chip (LOC) strategy has a strong potential to be used in the field, since they can be miniaturized and automated; also being potentially fast and extremely sensitive. There are still more than a few issues to be solved before in-field applications, including the pre-treatment of a sample, such as the enrichment of bacteria in culture broth, the proper storage of reagents, the full integration into a batterypowered system, the detection limit and the enhancement of the sensitivity of each method.

References

  1. Ganjavi M. Characterization of luminous bacteria as a biosensing element for detection of acrylamide in food.  2014.
  2. Indexed at, Google Scholar

  3. Nikhil B, Pawan J, Nello F, et al. Introduction to biosensors. Essays Biochem. 2016;60(1):1-8.
  4. Indexed at, Google Scholar, Cross Ref

  5. Justino CI, Freitas AC, Pereira R, et al. Recent developments in recognition elements for chemical sensors and biosensors. TrAC. 2015;68:2-17.
  6. Indexed at, Google Scholar, Cross Ref

  7. Silhavy TJ, Kahne D, Walker S. The bacterial cell envelope. Cold Spring Harb Perspect Biol. 2010;2(5):a000414.
  8. Indexed at, Google Scholar, Cross Ref

  9. Mocan T, Matea C, Tabaran F, et al. In vitro administration of gold nanoparticles functionalized with MUC-1 protein fragment generates anticancer vaccine response via macrophage activation and polarization mechanism. J Cancer. 2015;6(6):583.
  10. Indexed at, Google Scholar, Cross Ref

  11. Jain S, Hirst D, O sullivan J. Gold nanoparticles as novel agents for cancer therapy. Br J Radiol. 2012;85(1010):101–13.
  12. Indexed at, Google Scholar, Cross Ref

  13. Kim D, Jon S. Gold nanoparticles in image-guided cancer therapy. Inorganica Chim Acta. 2012;393:154–64.
  14. Indexed at, Google Scholar, Cross Ref

  15. Mocan L, Ilie I, Matea C, et al. Surface plasmon resonance-induced photoactivation of gold nanoparticles as bactericidal agents against methicillin-resistant Staphylococcus aureus. Int J Nanomed. 2014;9:1453–61.
  16. Indexed at, Google Scholar, Cross Ref

  17. Mouffouk F, Rosa da Costa AM, Martins J, et al. Development of a highly sensitive bacteria detection assay using fluorescent pH-responsive polymeric micelles. Biosens. Bioelectron. 26:3517–3523.
  18. Indexed at, Google Scholar, Cross Ref

  19. Massad-Ivanir N, Shtenberg G, Tzur A, et al. Engineering nanostructured porous SiO2 surfaces for bacteria detection via “direct cell capture”. Anal Chem. 2011;83(9):3282-9.
  20. Indexed at, Google Scholar, Cross Ref

  21. Yang X, Gu C, Qian F, et al. Highly sensitive detection of proteins and bacteria in aqueous solution using surface-enhanced Raman scattering and optical fibers. Anal chem. 2011;83(15):5888-94.
  22. Indexed at, Google Scholar, Cross Ref

  23. Raj V, Vijayan AN, Joseph K. Cysteine capped gold nanoparticles for naked eye detection of E. coli bacteria in UTI patients. Sens Bio-Sens Res. 2015;5:33-6.
  24. Indexed at, Google Scholar, Cross Ref

  25. Verdoodt N, Basso CR, Rossi BF, et al. Development of a rapid and sensitive immunosensor for the detection of bacteria. Food chem. 2017;221:1792-6.
  26. Indexed at, Google Scholar, Cross Ref

  27. Thiramanas R, Laocharoensuk R. Competitive binding of polyethyleneimine-coated gold nanoparticles to enzymes and bacteria: a key mechanism for low-level colorimetric detection of gram-positive and gram-negative bacteria. Microchim Acta. 2016;183(1):389–96.
  28. Indexed at, Google Scholar, Cross Ref

  29. Nag P, Sadani K, Mukherji S. Optical fiber sensors for rapid screening of COVID-19. INAE. 2020;5(2):233-6.
  30. Indexed at, Google Scholar, Cross Ref

  31. Rajapaksha P, Elbourne A, Gangadoo S, et al. A review of methods for the detection of pathogenic microorganisms. Analyst. 2019;144(2):396-411.
  32. Indexed at, Google Scholar, Cross Ref

  33. Arlett JL, Myers EB, Roukes ML. Comparative advantages of mechanical biosensors. Nat Nanotechnol.2011;6(4):203-15.
  34. Indexed at, Google Scholar, Cross Ref

  35.  Le TN, Tran TD, Kim MI. A convenient colorimetric bacteria detection method utilizing chitosan-coated magnetic nanoparticles. Nanomater. 2020;10(1):92.
  36. Indexed at, Google Scholar, Cross Ref

  37. Alvarez M, Zinoviev K, Moreno M, et al. Cantilever biosensors. In Optic Biosen.  2008; 419-452.
  38. Indexed at, Google Scholar, Cross Ref

  39. Yoo EH, Lee SY. Glucose biosensors: an overview of use in clinical practice. Sens. 2010;10(5):4558-76.
  40. Indexed at, Google Scholar, Cross Ref

  41. Nguyen HH, Lee SH, Lee UJ, et al. Immobilized enzymes in biosensor applications. Mater. 2019;12(1):121.
  42. Indexed at, Google Scholar, Cross Ref

  43. Mondal B, Ramlal S, Lavu PS, et al. Highly sensitive colorimetric biosensor for staphylococcal enterotoxin B by a label-free aptamer and gold nanoparticles. Front  microbiol. 2018;9:179.
  44. Indexed at, Google Scholar, Cross Ref

Get the App